Tag Archives: IDTE Buffer

Sample Prep – Withering Syndrome p18RK7 Plasmid Standard Curve Dilution

The withering syndrome standard curve on my last two qPCRs has been wonky, so I’m making a new curve.

Used the 3e7 dilution of p18RK7 from 20161128 as the “stock” to make serial, 1:10 dilutions (final volume of 1000uL in each tube).

I prepared the dilution series using IDTE (pH=8.0; IDT) Buffer. The original dilution worksheet below was set up by Nate Wight many, many, moons ago.

Dilution calcs (Google Sheet): 20160316 – WS p18RK7 plasmid dilution table

Will test out the new curve dilution shortly.

Share

Sample Prep – Withering Syndrome p18RK7 Plasmid Standard Curve Dilution

Lisa recently ran a qPCR and noticed that the standard curve had drifted quite a bit and was no longer usable, so I’m making more.

Used NcoI-linearized p18RK7 abalone withering syndrome plasmid (from 20120726) to make a fresh dilution series. The plasmid was most recently re-assessed and successfully used for a new standard curve on 20160316. As such, I re-used the dilution calculations from 20160316 (see sheet below).

I prepared the dilution series using IDTE (pH=8.0; IDT) Buffer. The dilution worksheet below was set up by Nate Wight many, many, moons ago.

Dilution calcs (Google Sheet): 20160316 – WS p18RK7 plasmid dilution table

Share

Sample Prep – Withering Syndrome p18RK7 Plasmid Standard Curve Dilution

We are virtually out of the withering syndrome qPCR standard curve plasmid dilutions and I need to send some to Colleen Burge at Univ. of Maryland Baltimore County. As such, I’ll need to make a fresh dilution series and test it out prior to sending to her.

Used NcoI-linearized p18RK7 abalone withering syndrome plasmid (from 20120726) to make a fresh dilution series.

Since it’s been nearly 4yrs since the plasmid was prepared, I decided to re-quantify the DNA using a Qubit3 (Life Technologies) in the Roberts Lab. Used the dsDNA BR Qubit reagents.

SAMPLE CONCENTRATION (ng/μL)
p18RK7 NcoI-linearized 29.0

The result is pretty close to what had been measured 4yrs ago (~26.1ng/μL – difference of  ~10%), so that’s good to see.

I prepared the dilution series using IDTE (pH=8.0; IDT) Buffer. The dilution worksheet below was set up by Nate Wight many, many, moons ago.

Dilution calcs (Google Sheet): 20160316 – WS p18RK7 plasmid dilution table

Share